NYSLYCY - YSLYCY

Categories: ,

Application Area

These oil resistant fl exible cables are used in all electrical equipments, electronic control systems, automation technologies, plant manufacturing, power station and others. Mainly for installation in dry, moist/wet rooms, especially in industrial environments, for average mechanical loads. It incorporates the inner sheath to maintain the cable in circular formation and minimize the space between cores. It’s tinned copper wire braiding provides shielding in places where electro magnetic interference and infl uence exist.

 

Cable Construction

ConductorFlexible Stranded Annealed Copper (IEC/EN 60228, VDE 0295, Class 5)
InsulationPVC (EN 50363-3, VDE 0207-363-3)
Core StrandingIn layers
ColoursOuter Sheath: Grey RAL7001 and other colours on request
Core Colours-JZ type; White numbered black cores with yellow-green earth conductor.
-OZ type; White numbered black cores without yellow-green earth conductor.
-JB type; Colored cores according to VDE 0293 with yellow-green earth conductor
-OB type; Colored cores according to VDE 0293 without yellow-green earth conductor
Outer SheathSpecial PVC (EN 50363-4-1, VDE 0207-363-4-1)
Inner SheathPVC
ScreenTinned Copper Wire Braid

 

Technical Characteristics

Min. Bending RadiusFixed: 8 x Cable Diameter, Flexible: 15 x Cable Diameter
Operating Voltage300 V / 500 V
Test Voltage3000 V
Temperature RangeFixed -30 °C ........+70 °C, Flexible: -5 °C ........+70 °C
Flame RetardancyIEC/EN 60332-1
Oil ResistanceIRM 902(4h,70°C)

 

Technical Tables

Number of Cores X Section
(nxmm²)
Outer Diameter
mm
Cable Weight
≈ Kg/Km
2 x 0,56.462.6
3 G 0,56.770.3
4 G 0,57.283.4
5 G 0,57.796
6 G 0,58.2110.4
7 G 0,58.2113.7
8 G 0,59.4144.5
9 G 0,510.0162.9
10 G 0,510.4177.7
12 G 0,510.7192.1
14 G 0,511.3216.8
16 G 0,511.9238.1
18 G 0,512.4262.7
19 G 0,512.4266.1
20 G 0,512.9287.6
24 G 0,514.6359
25 G 0,514.8372.4
27 G 0,514.8379.2
30 G 0,515.3406.7
32 G 0,515.8433.1
34 G 0,516.6469.4
36 G 0,516.6476.1
37 G 0,516.6479.5
25 G 0,7516.3472.7
27 G 0,7516.3482.8
30 G 0,7516.9522.4
32 G 0,7517.4555.9
34 G 0,7518.0592.2
36 G 0,7518.0602.4
37 G 0,7518.0607.4
40 G 0,7519.3686
2 x 17.284
3 G 17.696.8
4 G 18.1115
5 G 18.9140.8
6 G 19.6162.3
7 G 19.6169
8 G 111.0213.6
9 G 111.7239
10 G 112.2262.6
12 G 112.5286.3
14 G 113.1318.8
16 G 113.9359.8
18 G 114.5398.1
19 G 114.5404.8
20 G 115.2436
24 G 1,520.1753.3
2 x 2,59.3146.3
3 G 2,59.7173.5
4 G 2,510.5212
5 G 2,511.6257.8
6 G 2,512.6302.6
7 G 2,512.6318.6
8 G 2,514.5402.1
9 G 2,515.4453.7
10 G 2,516.3502.6
12 G 2,516.7557.3
14 G 2,517.5622.5
16 G 2,518.6706.6
18 G 2,519.5781.4
19 G 2,519.5797.4
2 x 410.4193.1
3 G 411.1241.1
4 G 412.1295.8
5 G 413.3362
6 G 414.4427.2
7 G 414.4453
8 G 416.6566.9
9 G 417.7639.9
Number of Cores X Section
(nxmm²)
Outer Diameter
mm
Cable Weight
≈ Kg/Km
40 G 0,517.5533.2
42 G 0,518.3578.7
45 G 0,518.8610.9
50 G 0,519.3649.7
52 G 0,519.3656.4
54 G 0,519.8686.9
56 G 0,519.8693.7
2 x 0,756.974.6
3 G 0,757.284.9
4 G 0,757.799.3
5 G 0,758.3116.2
6 G 0,759.1140
7 G 0,759.1145.1
8 G 0,7510.2177.9
9 G 0,7511.0204.8
10 G 0,7511.4223.2
12 G 0,7511.8242.1
14 G 0,7512.3269.4
16 G 0,7512.8298.5
18 G 0,7513.6334.7
19 G 0,7513.6339.8
20 G 0,7514.2365.8
24 G 0,7515.8447.3
24 G 117.1542.7
25 G 117.4562.9
27 G 117.4576.4
30 G 118.0621.4
32 G 118.8675.8
34 G 119.5720.2
36 G 119.5733.7
37 G 119.5740.5
2 x 1,58.1107.8
3 G 1,58.8131.9
4 G 1,59.4156.7
5 G 1,510.2186.5
6 G 1,511.2222.6
7 G 1,511.2232.2
8 G 1,512.6285.5
9 G 1,513.6330.1
10 G 1,514.2359.4
12 G 1,514.6395.1
14 G 1,515.3439.8
16 G 1,516.3496.5
18 G 1,517.1551.3
19 G 1,517.1560.9
20 G 1,517.9604.4
10 G 418.6710.2
12 G 419.2788.5
2 x 612.1270.7
3 G 612.8331.3
4 G 614.1414.7
5 G 615.4501.8
6 G 616.9603.4
2 x 1014.3399.5
3 G 1015.1496.1
4 G 1016.7628.6
5 G 1018.5773.3
2 x 1617.0587
3 G 1618.3749.3
4 G 1620.0938.9