RE-2X(St)H-fl PIMF-TIMF Instrumentation Cable

Do you have a question about

RE-2X(St)H-fl PIMF-TIMF Instrumentation Cable ?

Description

Baran Kablo’s RE-2X(St)H-fl PIMF-TIMF Instrumentation Cable is designed for use in electronic control systems, communication technologies, and the petrochemical industry. This cable is ideal for both indoor and outdoor applications, providing excellent performance for analog and digital signal transmission. RE-2X(St)H-fl PIMF-TIMF is especially suited for environments with high safety requirements, as it is manufactured with an HFFR (Flame Retardant and Self-Extinguishing) compound. This feature prevents the spread of flames and produces very little smoke in the event of a fire, thereby maximizing safety by preserving visibility during emergencies.

Additionally, the cable is equipped with PIMF (Pairs in Metal Foil) and TIMF (Triads in Metal Foil) structures. These configurations individually shield each pair and triad with metal foil, providing high-level protection against electromagnetic interference and enhancing signal integrity. This design is particularly beneficial in industrial environments with high levels of electromagnetic disturbances, ensuring reliable signal transmission and uninterrupted performance.

RE-2X(St)H-fl PIMF-TIMF Instrumentation Cable is engineered for technically demanding and safety-critical applications, standing out in the industry with its reliable and high-quality transmission solutions.

 

Cable Structure

Conductor Stranded Annealed Copper according to IEC/EN 60228, Class 2
(Class 1 or Class 5 and/or tinned upon request)
InsulationFrom XLPE to BS EN 50290-2-29
Core StrandingVeins twisted in layers in pairs, triplets or quadruplets
Outer Sheath ColorBlue or Black and other colors on request
Vein ColorsNumbered Pairs: Black/White, Numbered Triples: Black/White/Red and Numbered Quads: Black/White/Red/Blue
Outer Sheath HFFR Compound EN 50290-2-27
Screen Tinned Copper Drain Wire Individual and Bulk Al-PET Foil Grids

 

Technical Specifications

Min. Bending Radius Fixed: 7.5 x Cable Diameter
Operating Voltage 500 V
Test Voltage 2000 V
Temperature Range Fixed Fixed -40°C / +70°C, Flexible - 5°C / +50°C
Flame Retardancy IEC 60332-1-2 / IEC 60332-3-24 Cat. C

 

Technical Tables

COPPER CLASSNUMBER OF PERDIAMETERWEIGHT
CLASS 22x2x0,5010.20120
CLASS 23x2x0,5010.80120
CLASS 24x2x0,5011.80150
CLASS 25x2x0,5013.10190
CLASS 26x2x0,5014.30226
CLASS 210x2x0,5017.60325
CLASS 215x2x0,5021.50480
CLASS 22x2x0,7510.90142
CLASS 23x2x0,7511.60145
CLASS 24x2x0,7512.90190
CLASS 25x2x0,7514.10228
CLASS 26x2x0,7515.50285
CLASS 210x2x0,7519.10414
CLASS 22x2x111.40164
CLASS 23x2x112.20170
CLASS 24x2x113.60220
CLASS 25x2x114.80270
CLASS 26x2x116.30335
CLASS 210x2x120.14492
CLASS 22x2x1,512.20190
CLASS 23x2x1,513.20202
CLASS 24x2x1,514.40256
CLASS 25x2x1,516.00323
CLASS 26x2x1,517.50393
CLASS 22x2x2,514.70277
CLASS 23x2x2,515.90300
CLASS 24x2x2,517.50383
CLASS 25x2x2,519.40486
CLASS 26x2x2,521.40602